Operating modes |
Eddy Current Modes |
As AeroCheck+ Eddy Current, Single Frequency |
Display |
Modes |
X/Y Impedance Plane (Flying Spot) |
Waterfall |
||
Timebase Scan |
||
C-Scan |
||
Meter |
||
C-Scan |
Resolution |
Max size 1 million data points |
Scaling |
.1-999.9 Ticks/mm |
|
Typical Scan |
120 by 100 mm at 0.1mm resolution |
|
Data Saved |
Data stored as XY Pairs for 2 Channels. Data presentation X, Y, R or thet on CH1, Ch2 or Mix. |
|
Encoder |
Input |
6 Pin Lemo1B Connector. 2 phase 2 axis on way Lemo; =X/Y or R Theta . |
Count rate Max |
100kHz |
|
Data Storage |
Max Files |
As per AC+ |
C-SCan |
Max no of C-Scan Data Files 1,000 |
|
General |
Power |
8 hrs Battery Life and as per AeroCheck+ |
Physical |
As Per AeroCheck+ |
|
Save |
Inspection data to SD Card* |
|
Export |
Of inspection report |